DIRECT VENT, ZERO CLEARANCE
GAS FIREPLACE HEATER
MILLIVOLT STANDING PILOT
DVP(42,48)FP3(0,1,2,3)(N,P)-4
DIRECT IGNITION
DVP(42,48)FP5(0,1,2,3)N-1
INTERMITTENT PILOT
DVP(42,48)FP7(0,1,2,3)(N,P)-5
REMOTE RF
DVP(42,48)FP9(1,3)(N,P)-5
UL FILE NO. MH30033
INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL
WARNING: If not installed, operated and maintained
in accordance with the manufacturers instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
This appliance may be installed in
an aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by state or local
codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certied kit is used.
GAS-FIRED
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
Do not store or use gasoline or other am-
mable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbors phone. Follow the
gas suppliers instructions.
If you cannot reach your gas supplier,
call the re department.
Installation and service must be per-
formed by a qualied installer, service
agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Note: Barrier required, but may be sold separately.
HOT GLASS
DO NOT TOUCH
NEVER
WILL
CAUSE BURNS.
GLASS
UNTIL COOLED.
ALLOW CHILDREN
TO TOUCH GLASS.
WARNING
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
Page view 0
1 2 3 4 5 6 ... 71 72

Summary of Contents

Page 1 - AND OWNER’S MANUAL

Page 1DIRECT VENT, ZERO CLEARANCEGAS FIREPLACE HEATERMILLIVOLT STANDING PILOTDVP(42,48)FP3(0,1,2,3)(N,P)-4DIRECT IGNITIONDVP(42,48)FP5(0,1,2,3)N-1INTE

Page 2 - TABLE OF CONTENTS

31455-8-0415Page 10CLEARANCESClearance to CombustiblesBack 0" (0 mm)Side 0" (0 mm)Floor 0" (0 mm)Top Stand-off 0" (0 mm)Top Framin

Page 3 - IMPORTANT SAFETY INFORMATION

31455-8-0415 Page 11Figure 7NOTICE: Island and Room Divider installation is possible as long as the horizontal portion of the vent system does not ex

Page 4 - LP-GAS WARNING ODOR

31455-8-0415Page 12GAS SUPPLYThe gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas

Page 5

31455-8-0415 Page 13INSTALLATIONFraming and Finishing 1. Choose unit location.2. Frame in replace with a header across the top. It is important to

Page 6 - INTRODUCTION

31455-8-0415Page 14INSTALLATIONFlush Mount Mantel InstallationThe replace must extend 3/4” beyond nished wall surface when using a ush mount mantel

Page 7 - SPECIFICATIONS

31455-8-0415 Page 15INSTALLATIONFlush Wall InstallationFigure 15Combustible Surround InstallationFigure 16Note: For mantelshelf requirements, see Figu

Page 8 - VENT SYSTEM IDENTIFICATION

31455-8-0415Page 16INSTALLATIONREAR ONLY, STRAIGHT OUT THE BACK"A" "B" MODEL 6"(152mm) 5 1/8"(130mm) to 6 /2"(165mm

Page 9 - SPECIAL VENT SYSTEMS

31455-8-0415 Page 17To Use the Vent Graph1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent

Page 10 - CLEARANCES

31455-8-0415Page 18VENTING FIREPLACE - TOPBelow Grade InstallationWhen it is not possible to meet the required vent terminal clearances of 12” (305mm)

Page 11 - LOCATING FIREPLACE

31455-8-0415 Page 19Figure 26MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACEF

Page 12 - GAS SUPPLY

31455-8-0415Page 2TABLE OF CONTENTSIMPORTANT SAFETY INFORMATION ...

Page 13 - INSTALLATION

31455-8-0415Page 20Figure 29Figure 30Figure 31EXAMPLES - TOP VENT RUN

Page 14

31455-8-0415 Page 21VENTING EXAMPLES WHEN USING DVA47 ADAPTORVertically Off Top of Fireplace OnlyExampleH1 = 2ftV1 = 20ftH = 2ft V = 20ftDVA47 ADAPTO

Page 15

31455-8-0415Page 22 Acceptable vertical and horizontal vent run. Unacceptable vertical and horizontal vent run.Figure 35Venting Graph (Dimensions in

Page 16

31455-8-0415 Page 23Figure 36Figure 37Figure 38Figure 39Model Maximum Pipe Length H1DVP42 24"DVP48 24"Model Maximum Pipe Length H1DVP42 24&q

Page 17 - VENTING FIREPLACE - TOP

31455-8-0415Page 24REAR VENT CONVERSIONConverting ue take-off to rear ventingWhen switching out the ue and inlet vent collars to run horizontally of

Page 18

31455-8-0415 Page 25Figure 41A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum]B = clearance to window or do

Page 19

31455-8-0415Page 268" VENTING FRAMING AND FINISHINGInstalling Support BracketsA horizontal pipe support MUST BE used for each 3 feet of horizonta

Page 20 - EXAMPLES - TOP VENT RUN

31455-8-0415 Page 278" VENTING FRAMING AND FINISHING (continued)Figure 44Figure 45Figure 46See Horizontal Termination Page 31 and Vertical Termin

Page 21 - DVA47 ADAPTOR

31455-8-0415Page 286 ⅝" VENTING FRAMING AND FINISHINGInstalling Support BracketsA horizontal pipe support MUST BE used for each 3 feet of horizon

Page 22 - VENTING FIREPLACE - REAR

31455-8-0415 Page 296 ⅝" VENTING FRAMING AND FINISHING (continued)Figure 50Figure 51See Horizontal Termination Page 31 and Vertical Termination o

Page 23 - EXAMPLES - REAR VENT RUN

31455-8-0415 Page 3DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLEDBefore enclosing the vent pipe assembly, operate the appliance to

Page 24 - REAR VENT CONVERSION

31455-8-0415Page 30Termination clearance for buildings with combustible and noncombustible exteriors.Vertical Sidewall InstallationsImportant! Minimum

Page 25 - VENT CLEARANCES

31455-8-0415 Page 31NOTE: Termination cap should pass through the wall restop from the exterior of the building. Adjust the termination cap to its 

Page 26

31455-8-0415Page 32VERTICAL TERMINATIONLocate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this

Page 27

31455-8-0415 Page 33VERTICAL TERMINATIONInstalling the Vent System in a ChaseA chase is a vertical box-like structure built to enclose the

Page 28

31455-8-0415Page 34NOTICE: For top vent installation only: Use of a DVA47 adap-tor is required.CAUTION: Sharp edges, use protective gloves when insta

Page 29 - Figure 51

31455-8-0415 Page 35DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONSFigure 60Figure 617. Remove outside mounting plate with tube attached from wall. Mark

Page 30 - TERMINATION CLEARANCES

31455-8-0415Page 36Follow correct option according to venting method.Connecting Directly to FireplaceIf the air inlet and ue outlet tubes are to be c

Page 31 - HORIZONTAL TERMINATION

31455-8-0415 Page 37DVVK-5F FLEX VENT INSTRUCTIONSThe DVVK-5F FLEX VENT KIT includes the following compo-nents:• (1) Horizontal Termination Cap• (

Page 32 - VERTICAL TERMINATION

31455-8-0415Page 38Model AIR SHUTTER SETTINGSBURNER ORIFICEOpening "A" Propane/LP OriceDVP42 Full Open #52DVP48 Full Open #51Maxitrol Valve

Page 33

31455-8-0415 Page 39LOG PLACEMENT (4 LOG SET)Before you begin: If you are installing logs into the DVP42 or DVP48 model then this replace is supplied

Page 34

31455-8-0415Page 4Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must nd out if you can smell

Page 35

31455-8-0415Page 40The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the g

Page 36

31455-8-0415 Page 41STANDING PILOT OPERATING INSTRUCTIONS Remote/Off/On SwitchThe replace is equipped with a Remote/OFF/ON switch. A wire harness is

Page 37

31455-8-0415Page 42Figure 75MILLIVOLT SYSTEM STANDING PILOT WIRING DIAGRAM

Page 38 - PROPANE/LP GAS CONVERSION

31455-8-0415 Page 431. Stop! Read the safety information above.2. Set REMOTE/OFF/ON switch to OFF.3. Turn off all electric power to the appliance

Page 39 - LOG PLACEMENT (4 LOG SET)

31455-8-0415Page 44With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do

Page 40

31455-8-0415 Page 45A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the oor because some gas is heavier tha

Page 41

31455-8-0415Page 46LED CODESSteady ON Normal operation, power ON to control2 Flashes 3 unsuccessful ignition trials3 Flashes Main burner ame failed 4

Page 42 - Figure 75

31455-8-0415 Page 471. Remove glass door and place away from the replace.2. Turn on gas shut off valve. Follow ignition procedure.3. If burner doe

Page 43 - TO TURN OFF GAS TO FIREPLACE

31455-8-0415Page 48The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in ac

Page 44

31455-8-0415 Page 49IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS5.25 VDC ELECTRONIC CONTROL VALVEThe electronic control valve system includes the abil

Page 45 - TO TURN OFF GAS TO APPLIANCE

31455-8-0415 Page 5REQUIREMENTS FOR MASSACHUSETTSFor all side wall horizontally vented gas fueled equipment installed in every dwelling, building or s

Page 46 - OPTIONAL REMOTE CONTROL

31455-8-0415Page 50IPI ELECTRONIC SYSTEM WIRING DIAGRAMIf any of the original wire as supplied with this unit must be replaced, it must be replaced wi

Page 47 - PURGE PROCEDURE

31455-8-0415 Page 51TO TURN OFF GAS TO FIREPLACEGAS COCK1. STOP! Read the safety information above.2. Turn OFF electric power to the appliance.3. R

Page 48

31455-8-0415Page 52Brief Description of the ComponentsThe gas valve is tted with a manual HI/LO knob to allow for man-ual modulation of the gas outle

Page 49

31455-8-0415 Page 531If the DFC giving signal lock out:The board should be unlocked toreinitiate a pilot flame ignition (forthe correct unlock sequenc

Page 50

31455-8-0415Page 54INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING

Page 51

31455-8-0415 Page 55RF VALVE OPERATION (AF-4040 Electronic Gas Valve system only)Please refer to the separate instructions for detailed operation and

Page 52

31455-8-0415Page 56MAINTENANCEMaintenance frequency must be determined individually for each application. Some considerations are:• Exposure to water

Page 53 - 31455-8-0415 Page 53

31455-8-0415 Page 57Figure 79RF WIRING DIAGRAMNote: For "RF" Fireplace models with Premium Multi-Function Remote Control, Refer to the sepa

Page 54 - 31455-8-0415Page 54

31455-8-0415Page 58FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSIN

Page 55 - RF OPERATING INSTRUCTIONS

31455-8-0415 Page 59MAINTENANCE AND SERVICEPlease NoteIt is normal for appliances fabricated of steel to give off some expansion and/or contraction no

Page 56 - RF MAINTENANCE INSTRUCTIONS

31455-8-0415Page 6Instructions to Installer1. Installer must leave instruction manual with owner after installation.2. Installer must have ow

Page 57 - RF WIRING DIAGRAM

31455-8-0415Page 60DVP42FP(3,5,7,9) PARTS LISTIndex No.Part NumberDescriptionDVP42FP3 DVP42FP5 DVP42FP7 DVP42FP91 R7654 R7654 R7654 R7654 Insulation,

Page 58

31455-8-0415 Page 61DVP42FP(3,5,7,9) PARTS LIST41 R3436 - R2522 - Remote/On/Off Switch43 - R7615 - Cord Set44 - R8144 - - Wire Harness (DI)45 - - R111

Page 59 - MAINTENANCE AND SERVICE

31455-8-0415Page 62DVP48FP(3,5,7,9) PARTS LISTIndex No.Part NumberDescriptionDVP48FP3 DVP48FP5 DVP48FP7 DVP48FP91 R7654 R7654 R7654 R7654 Insulation,

Page 60 - DVP42FP(3,5,7,9) PARTS LIST

31455-8-0415 Page 63 Use Only Manufacturer’s Replacement Parts. Use of Any Other Parts Could Cause Injury Or Death.DVP48FP(3,5,7,9) PARTS LIST44 - R81

Page 61

31455-8-0415Page 64PARTS VIEW

Page 62 - DVP48FP(3,5,7,9) PARTS LIST

31455-8-0415 Page 65To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provid

Page 63

31455-8-0415Page 66Attention: Install blower assembly before connecting gas inlet supply lineNote: Junction box on right side of replace must be p

Page 64 - PARTS VIEW

31455-8-0415 Page 671 R7731 BLOWER MOTOR2 31920 SWITCH ASSEMBLY3 R4192 SPEED CONTROL KNOB4 R4186 SPEED CONTROLFBB4 OPTIONAL VARIABLE SPEED BLOWER INST

Page 65 - HOW TO ORDER REPAIR PARTS

31455-8-0415Page 681. Using gloves, unpack liner components and check for damaged or missing components.2. Lower bottom louver and remove upp

Page 66

31455-8-0415 Page 69The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond w

Page 67 - 4 R4186 SPEED CONTROL

31455-8-0415 Page 7Remote Control Options & AccessoriesDescriptionFRBC Millivolt/IP Battery Remote ON/OFFFRBTC Millivolt/IP Battery Remote T-StatT

Page 68

31455-8-0415Page 70Web Site www.empirecomfort.comEmpire Comfort Systems918 Freeburg AvenueBelleville, Illinois 62220-2623CLEARANCES TO COMBUSTIBLESGA

Page 69 - ACCESSORIES

31455-8-0415 Page 71Web Site www.empirecomfort.comEmpire Comfort Systems918 Freeburg AvenueBelleville, Illinois 62220-2623FRAMING DIMENSIONFIREBOX DI

Page 70 - Fireplace Heater

31455-8-0415Page 72WARRANTYEmpire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the peri

Page 71

31455-8-0415Page 8VENT SYSTEM IDENTIFICATIONFigure 1Begin the vent system installation by selecting the type of venting to be installed and the path t

Page 72 - WARRANTY

31455-8-0415 Page 9The following vent systems are acceptable for use with the DVP (42,48) series replaces:Simpson Duravent® GS 5" - 8&