ww ww ww .. ll uu mm aa cc ee ll ll .. cc oo mmI n d u s t r i a lC a t a l o g u e
10Although IP is mainly a Europeanrating system, it is referred tomore and more in North America,especially for lighting xturesneeding a wet location
C A T A L O GP r o d u c t s
12P r o d u c t sLER-HZ SeriesHazardous Location Exit Sign Class I Zone 2Extremely resistant to water, strong impacts, vibrations and variations in te
MQM-NX SeriesRemote Fixture - Water Proof NEMA-4X SeriesA complete emergency lighting solution, these products are designed for use in a widerange of
Zone Sensing VSR SeriesThe VSR (Voltage Sensing Relay) option activates all of the emergencylighting if only one, multiple or all zones become de-ener
C A T A L O GE x i t S i g n s
16R G 1 2 S - E S e r i e sSupply and install a unit thatcombines an illuminated LED exitsign with an emergency light batteryunit. The housing and f
17R G 1 2 S - E S e r i e s*ALINGAP (AlInGaP): Aluminum, Indium, Gallium and Phosphorus. ALINGAP LEDoffers a higher light efficacy, with the Lumen/Wa
18L E R - H Z S e r i e sSupply and install Lumacell LER-HZSeries LED exit signs. The equipmentshall operate with universal two-wireAC input voltag
19L E R - H Z S e r i e sDimensionsPower ConsumptionModelAC Specs DC SpecsAC/DC redAC/DC greenSelf-powered redSelf-powered green120 to 347Vac120 to
R S T P S e r i e sTransferPanelsLERE-XP SeriesHazardous LocationExit Signs20CSA certified for use in hazardous locationsClass I, Zone 1, Groups IIC,
LERE-XP Series & RSTP Series21DimensionsOrdering InformationDOUBLE PENDANT MOUNTSEVERITY S3, S4 SEVERITY S1, S2CEILING MOUNTPENDANT MOUNTNo Severi
22L E R E O B 1 2 L S e r i e sFeatures• Certified NEMA-3R • Gasketed fiberglass housing designed specifically for industrialapplications• Gray finish i
23L E R E O B 1 2 L S e r i e sOrdering InformationLEREO1W4T B12L UNIVModel Lettering VoltageLEREO1W4T =single face NEMA-3R, exit/sortieLEREO2W4T =d
24LT E U S e r i e sFeatures• Illumination provided by borosilicate glass tubes, internally coatedwith zinc sulphide phosphor and filled with tritium
25Ordering InformationLTEU 1Series Faceplates/Mounting Housing Colour Life Years OptionsLTEU = exitLTB3LE/S = exit/sortiLTB3LS/E = sortie/exit 1 = si
26Combo Unit NEMA-4X Certified Combo UnitFeaturesStandard• NEMA-4X Certified for wall or ceiling mount• High efficiency MR16 halogen lamps up to 12V, 12W
DC Specs6V-36W Min. 30 minutes12V-60W Min. 30 minutesModel3LER35LER3AC Specs120/347Vac Less than 10W120/347Vac Less than 10W27Power ConsumptionTypic
28Exit SignNEMA-4X Certified Exit SignFeatures• Polymeric enclosure is fully gasketed around lens and canopy toprevent water infiltration - NEMA-4X Cert
460.0079 Wall Mount460.0027 End Mount460.0028 Ceiling Mount29L E R 3 0 0 0 S e r i e sDC Specs6 to 48Vdc Less than 2W6 to 48Vdc Less than 2WNiCad ba
C A T A L O GS p e c i a l C o l l e c t i o n
30R G - X S e r i e s H a z a r d o u s L o c a t i o nFeatures• CSA Certified for use in hazardous locations:• Class I, Divisions 1 and 2, Groups
31R G - X S e r i e s DimensionsBefore ordering, identify theenvironment of your application:Class___, Division___, Group___. Referto the following
32Features• Certified Class I Division 2, Groups A, B, C and D as per CSA C22.2No.137-M19811, Class I, Zone 2, Groups IIC, IIB and IIA• Certified temper
Model AC SpecsWattage Capacity30 min. 1 hr. 1.5 hrs. 2 hrs. 4 hrs.3LERHZ 120/347 Vac 0.15 / 0.06 Amp 36 21 15 12 -3LERHZN 120/347 Vac 0.15 / 0.06 Amp
C A T A L O GR e m o t e s
36M Q M - H Z S e r i e sHAZARDOUS LOCATION Compliant Remote FixtureClass I, Division 2, Groups A, B, C and DClass I, Zone 2, Groups IIC, IIB and II
37M Q M - H Z S e r i e sDimensionsOrdering information4.5/8”[11.7cm]7.1/8”[18.1 cm]5.7/8”[14.9cm]3.3/4”[9.5cm]2.1/8”[5.4cm]4” JUNCTION BOXJUNCTION
38Features• Delivers unsurpassed pathway illumination – 70 feet, center-to-center (with 12V 20W lamp)• Fully gasketed cast aluminum back plate with cl
39Ordering InformationMQM1NX 6V6WSeries Lamp/Wattage ColourMQM1NX =single, NEMA-4XMQM2NX =double, NEMA-4X 6V6W = 6V-6 watts, MR166V10W = 6V-10 watts,
40S a f - T- R a y S e r i e sW a l l M o u n t R e m o t e H e a dRobust, vandal resistant, versatile wall mount fixtureFeatures• Compact wall
M Q M - H Z S e r i e s41SAF M 12V12WSeries Lamp Type Voltage/Wattage Colour OptionsSAF = exteriorremoteBlank = (1) med. base socketonly (max. 60W),
42R S 1 0 X P S e r i e sHazardous Location Remote Lighting FixturesCSA certified for use in hazardous locationsClass I, Zone 1, Groups IIC, IIB and II
Certification Guide for Remote Lighting Fixtures (40°C ambient)43DimensionsDOUBLE PENDANT MOUNTSEVERITY S1, S2, S3SEVERITY S3, S4CEILING MOUNT WALL MOU
MT-W4T SeriesNEMA 4X listed, surface-mounted, square industrialremote fixtureAvailable withtungsten or quartz lamps insingle or double headconfiguration
45W e a t h e r p r o o f S e r i e sMT-W4T SeriesDimensionsRS-WPRB SeriesDimensionsRS10-WPRB:45/8" (11.8 cm) L x 73/8" (18.6 cm) H x 41/8&q
Cubic, vandal-resistantsurface-mounted fixtureSingle, double or twin cubewith center bodyAvailable in factory white(standard) and black withfrosted pol
47RSQB/RSQBD/RSQB2 SeriesDimensionsRSQB: 43/4” (12.1 cm) L x 47/8” (12.4 cm) H x 43/4” (12.1 cm) DRSQBD: 91/2” (24.1 cm) L x 57/8” (15.0 cm) H x 43/4”
C A T A L O GB a t t e r y U n i t s
I N D E XS p e c i a l C o l l e c t i o n1. Hazardous Locations - C.E.C. Classications... 062. IP Rating ...
50R G S - D T S e r i e sFeatures• Solid-state pulse-type charger – current-limited, temperature-compensated, short-circuit proof and reverse-polari
51R G S - D T S e r i e sabcdefDimensionsOrdering InformationEXAMPLE: RGS 36 DT 2 RB9W AT / RG12S 72 DTF 2 RBQ8W AT / RG24S 350 DT FG 2 LHQ20W ATRG
52Battery Unit NEMA-4X Certified Battery UnitFeaturesStandard• Delivers unsurpassed pathway illumination – 70 feet, center-to-center(with 12V 20W lamp)
53Accessories (order as a separate item)R G - N X S e r i e sOrdering InformationRGNX 36 2 M6WSeries Capacity # of Heads Lamp/Wattage Colour A.C./V
54Features• Certified Class I Division 2, Groups A, B, C and D as per CSA C22.2No.137-M19811, Class I, Zone 2, Groups IIC, IIB and IIA• Certified temper
R G - N X S e r i e sDimensionsModel AC SpecsWattage Capacity30 min. 1 hr. 1.5 hrs. 2 hrs. 4 hrs.RGHZ36 120/347 Vac 0.17 / 0.06 Amp 36 21 15 12 -RG1
56Features• IP65 rated for wet and damp locations• Polycarbonate enclosure and lens, vandal resistant and UV stabilizedRust proof hardware• Ceiling, s
I P LT MS e r i e s5736” [91cm]33/4” [10cm]503/4” [129cm]63/4”[17cm]DimensionsOrdering InformationIPL 8Series Lamp type*A.C./VoltageAccessoriesIPL =48
C A T A L O GO p t i o n s & A c e s s o r i e s
6Hazardous Locations — C.E.C. ClassificationsC.E.C. Code ChangesIn 1998, the Canadian ElectricalCode®(C.E.C.) adopted theInternational Electrotechnical
60In an existing or new installation where exit signs andemergency lighting may be supplied by a single 120VDC sourceusing a common negative wire and
61Canada. Limit room ambienttemperature between 0oC to35oC (32oF to 95oF).Optimum systemperformance occurs at 25oC(77oF). A battery service lifeis de
Lumacell’s Central DC Systems are utilized where a largenumber of remote heads or standard 120 Volt DC fixtures suchas incandescent lamps may
DC Central Systems63Other OptionsOptional Alarms• Fuse/Circuit Breaker Open/TripAlarmBatteriesSealed Maintenance-Free LeadAcid Gas Recombination (SL S
64SL Series: Sealed Maintenance Free Lead Acid Battery Capacity Chart @25°CCabinet dimensions forsealed lead acid batteriesNominal Backup CapacityMode
Standard Features65CODE DESCRIPTIONGL Ground leakage.FC One set of dry contacts for remote fault sensing.RAP Remote alarm panel.SPF Drip shield (2.5”
66V S R S e r i e sTypical VSR-4(120)-1(120)-EXT WiringTypical Specification OperationThe VSR (Voltage SensingRelay) option activates all ofthe emerg
67V S R S e r i e sOrdering Informatione.g.VSR - 5 (347) - 1(120) -INTSeriesAC voltage ofzones AC voltageof PacksCabinet OtherOptionse. g. VSR# o
What Nexus can do for youNexus is a real-time emergency lighting monitoring and control system which offers buildingowners/managers control over thei
69Easy to use Graphic User Interface – The Nexus softwarecontains an easy to use graphic user interface which guidesthe user through a series of funct
Class I — (continued)Zones• Zone 0 — Class I locations inwhich explosive gas atmospheresare present continuously or arepresent for long periods.• Zone
All information and specifications containedin this catalogue are subject to change dueto engineer design, error and omissions.Illustrations and diagr
8Division Gas Groups• Group Aacetylene• Group Bbutadiene, ethylene oxide, hydrogen, manufactured gasescontaining more than 30% hydrogen (by volume),pr
9Class II — Dust EnvironmentsLocations which are deemed hazardousdue to the presence of combustible orelectrical conducting dusts.Class II locations n
Comments to this Manuals